Drilling Rig
Pumping Unit
FK125-3 / FKQ320-4 / FKQ480-5 /  FKQ640-6 / FKQ800-7 / FKQ1280-7 / FKQ1800-14
Request a Quote
Introduction

The ground blowout preventer control device meets the requirements of the petroleum industry standards and has the right to use the API SPEC 16D (Drilling Control Equipment Control System and Diversion Equipment Control System) emblem. The product has multiple models and comprehensive functions, meeting the requirements for regular use.


The remote console is equipped with two independent power sources. According to different configurations, provide electric oil pumps with different displacements, pneumatic oil pumps, or manual oil pumps. The design of the accumulator group meets the control requirements of closing all blowout preventer groups and opening hydraulic valves. The accumulator system is designed such that when one or a group of accumulators fail, the capacity loss does not exceed 25% of the total capacity, and can provide accumulators with ASME inspection marks.


The control device with manual pressure regulating valve has remote pneumatic pressure regulation function. When the gas source suddenly fails, the control pressure can automatically return to the initial set value. There is a backup pressure source interface on the control manifold of the remote console, which can introduce a pressure source when needed. A nitrogen backup system can be provided as needed to provide emergency auxiliary energy for the control manifold. When the accumulator and/or pump device cannot provide sufficient power fluid for the control manifold, a nitrogen backup system can be used to provide high-pressure gas to the manifold in order to close the blowout preventer. The nitrogen backup system can also provide emergency gas source for the drilling rig and auxiliary control console in case of emergency.

Parameter
Specification and models of Accumulators BOP
Discription Type & Parameters
FK125-3 FKQ320-4 FKQ480-5 FKQ640-6 FKQ800-7 FKQ1280-7 FKQ1800-14
Working Pres. 21 Mpa 21 Mpa 21 Mpa 21 Mpa 21 Mpa 21 Mpa 21 Mpa
Volume of tank 440L 790L 1100L 1290L 1600L 1600L 528gal
Elec-pumpoutput 20L/min 35L/min 46L/min 46L/min 46L/min 46L/min 42L/minx2
Dynamo power 7.5KW 11KW 18.5KW 18.5KW 18.5KW 18.5x2KW 18.5KW
Output & QTY.of
Gas-operated pumn
ManualPump 18mL/min 60mL/min 60x2mL/min 60x2ml/min 60x2mL/min 60x2mL/min 8L/min X3
Pres.& QTY. of
Gas-operated pumn
21 Mpa 21 Mpa 21 Mpa 21 Mpa 21 Mpa 21 Mpa 10.5MPaX3
Air source pres.
of gas-operated pump
0~1.6 Mpa 0~1.6 Mpa 0~1.6 Mpa 0~1.6 Mpa 0~1.6 Mpa 0~1.6 Mpa 0.53 ~0.8MPa
Maxim airconsumption of
gas-operatod pump
1.2m3/min 2.3m3/min 2.9m3/min 3.4m3/min 3.8m3/min 4.1m3/min 4.5m/min
Accumulator
volume & structure
25LX5 40LX8 40LX12 40LX16 80LX10 80LX16 80Lx16
Distribute
bisymmetrically
Charging pres.of
accumulator nitrogen
7±0.7 MPa 7±0.7 MPa 7±0.7 MPa 7±0.7 MPa 7±0.7 MPa 7±0.7 MPa 7±0.7 MPa
Overall
dimension
2.76X1.9X2.37M 4.16X2.06X2.56M 5.16X2.06X2.56M 5.46X2.21X2.56M 5.46X2.31X2.67M 6.45X2.65X2.68M 8.5X2.5X2.7M
Total weight 2.3T 5.07T 6.4T 7.7T 8T 11T 18.5T
We're here to help...
Got a project? Let's talk.
EXPERIENCE THE MORE
Get in Touch